NEW RIDGE TECHNOLOGIES NRT-8000 CALIBRATION and NEW RIDGE TECHNOLOGIES NRT-8000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the NEW RIDGE TECHNOLOGIES NRT-8000 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

 
For Sale New, List Price $8,990.00   NEW RIDGE TECHNOLOGIES NRT-8000   Description / Specification:    
NEW RIDGE TECHNOLOGIES NRT-8000 1527.2 to 1565.5 nm Handheld Optical Spectrum Analyzer

The New Ridge Technologies NRT-8000 is World's smallest OSA at the announcement (Oct. 1, 2013). With built-in reference for each single sweep, the NRT-8000 boasts excellent wavelength/frequency (±3.0 GHz or 0.0024nm) across the entire wavelength range. The rugged and compact design is perfect for outside plant (OSP) and military field applications. The integrated Server-Client (TCP/IP) software offers flexible remote control capabilities over the internet. The NRT-8000 is truely a universal OSA at affordable price. The NRT-8000 control software boasts the most simplified graphical user interface desgin. Without complex menu, the operator can start working on this instrument without learning curve. The control software is compatible with Windows XP, Windows 7 and Windows 8 that will meet vast majority of customers' requirements in the lab, in the systems and in the field. Specifications. Wavelength (Frequency) Coverage: 1527.2 nm to 1565.5 nm (196.3 THz to 191.5 THz). Absolute Wavelength (Frequency) Accuracy: ± 3.0 GHz (0.024nm). Optical Resolution (Line-width of Tunable Filter Shape): < 3.5 GHz (0.028nm) (Full width at half maximum (FWHM) of the tunable filter shape). Absolute Power Accuracy: ± 0.5 dB or better. Polarization Dependent Loss (PDL): < 0.4 dB. Optical Power Handling: +9 dBm (Operating Limit), +21 dBm (Damage Threshold). Optical Noise Floor Below: - 70 dBm (no input light). Optical Return Loss: > 30 dB. Scan Speed: < 0.5 second (for power and wavelength data only), < 5 seconds (for high-resolution spectrum and data). Communication Interface: USB 2.0 (USB 1.0 compatible). Weight < 2 Ib (less than 900 g).



 

Standard Calibration $475.00 *
*This is a Web introductory price for one calibration of the NEW RIDGE TECHNOLOGIES NRT-8000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chromatic Dispersion
Chromatic Dispersion is a broadening of the input signal as it travels down the length of the fiber. Chromatic Dispersion results from a variation in propagation delay with wavelength, and is affected by fiber materials and dimensions.

Detector
A Detector is a signal conversion device that converts power from one form to another, such as from optical power to electrical power

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Polarization Mode Dispersion (PMD)
Polarization mode dispersion (PMD) is a form of modal dispersion where two different polarizations of light in a waveguide, which normally travel at the same speed, travel at different speeds due to random imperfections and asymmetries, causing random spreading of optical pulses. It is he difference between the maximum and minimum values of loss typically measured in ps/km^1/2.


Please contact us for your NEW RIDGE TECHNOLOGIES NRT-8000 CALIBRATION and/or NEW RIDGE TECHNOLOGIES NRT-8000 1527.2 to 1565.5 nm Handheld Optical Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.